Note: Contact your Network Administrator to determine
which time server protocol and time server IP address to
use. If there is no time server on the site network, go to
Manual Time Setup.
3. In the IP of Host Name field, enter the IP address of the server to be used for time sync.
Note: The time server should run on a server that is either
on the same network as the sensor (requires no internet
connectivity) or on a server that has a public IP address
(requires internet connectivity). The time server sets the
sensor time to UTC time, therefore the time server can be
running in any time zone.
4. Enter the Port number from which the sensor should attempt to get a time synchronization. The
default port depends on the protocol selected:
Protocol Default Port
Brickstream 2010
Daytime 13
SNTP 123
Note: To use the Brickstream proprietary time sync
protocol you must use Device Manager to provide the
time sync. The time synchronization port and data delivery
port can be sent to the same IP address and port if
necessary, except when opting for either daytime or SNTP
protocol.
5. From the Time Zone drop-down, select the time zone of the sensor.
6. Click Save.
7. Click Sync Now to test the connection of the time sync server. A time sync request is
immediately sent to the IP address and port specified on the Date and Time Info page. A success
or failure message is displayed at the top of the page.