Brickstream® 3D Gen 2 Version 6.2
6/25/2021
©2016-2021 FLIR Integrated
Imaging Solutions Inc.
All rights reserved.
Brickstream® 3D Gen 2 Installation Guide
June 2021
66
register the sensor to a site. Please consult the Device Manager documentation, or contact support for
assistance.
Note: These settings are also available through the Configuration
Wizard.
There is a Reset link that returns you to the last saved settings. You may have to refresh the page.
1. Open the web interface to the Settings> Device Identification page.
2. Enter the following information:
a. Site ID—classification for a store or site number.
b. Site Name—classification for a store or site name.
c. Division ID—classification to identify this sensor within a group of locations.
d. Sensor ID—an alphanumeric code to uniquely identify the sensor within a site.
e. Sensor Name—a brief name for the sensor.
3. From the LEDStatus Lights drop-down, select if you want LED lights to be always on, or to turn
off after a defined time following a reboot. If a time is selected, the LEDlights are on during the
reboot to verify the startup sequence and then turn off once the selected time has passed.
4. From the XMLData Format drop-down, select a format to use for output data. The default (and
recommended) selection is Latest. More detailed information about XML formats can be found in
the Programmer's Guide.
5. Click Save.