3. Installation and operating instructions
3.1. Installation instructions for permanent water mains connection*
3.1.1. Security advice
The permanent water mains connection is to be installed and connected by a specialist!
To avoid short-circuits, make sure the water supply lines and power cables are not in
contact with or routed past a heat source; contact would cause them to melt.
If a valve leaks or if other water connections are used, turn off the water supply and
contact a specialist.
Do not clean the machine or any of its parts in a dishwasher.
Always turn off the permanent water mains connection overnight; turn off the water
supply if the machine is not to be used for a longer period of time.
3.1.2. Permanent water mains connection in the water tank*
The kit (Art. No. 1P 315 005) comprises:
- Electronic unit (1) (clip), for regulating and monitoring the water level in the water
tank
- Connecting cable (2) for the machine s internal 12 V DC power supply
- Control unit (3) (valve block)
- Operating Instructions, with maintenance notes (not shown)
Internal power supply
(*Not available in the US)
Elektronic-
unit
(1)
Connecting cable(2)
Control unit(3)