TD-100356.doc 26 / 32
If the error was remedied, you have to enter the service stamp.
Press the Service stamp key.
Date
D:02 M:02 Y:2001
Enter the service date and confirm with the ENTER key.
Use the arrow key to change to the service stamp entries. The errors and work codes are listed
in the appendix.
After you have made the entries, change to the menu Write coffee”.
Press the Write coffeekey. The service stamp is now entered in the Flair and any history bits
entries are set to zero.
Please wait
Terminal à Coffee
The Entry and Exit diagnoses are now completed.
Save diagnosis data to the chip card
Insert the chip card into the chip card reader of Terminal 3000.
Press the Read coffee key.
Please wait
Coffee --> Terminal
Terminal ready
Data is loaded
Now press the Write card key to save the data to the chip card.
Overwrite card?
Confirm this message with the ENTER key. If there is still data on the chip card that you need,
replace it with another one and begin again at point 13.
Write the card atData”.