13
Connecting the internal power supply
Connect connecting cable (2) to electronic
unit (1)
Plug connector of connecting cable (2) on
rear panel of machine, as illustrated
3.1.5. Commissioning
Caution! If the red LED is lit, check the following:
- Is the electronic unit correctly in place in the water tank?
- Water level (water level must not exceed half the water tank.)
- Scale build-up of the electronic unit; de-scale if necessary
Process Response of the LED on the electronic
unit
A
The microswitch opens the valve of the
electronic unit.
LED off
B
The water tank fills up with water and
the operating float switches the valve
off once the level is reached.
LED off
C
If the operating float jams, e.g. due to
scale build-up, the water level
continues to rise until the safety float
switches the valve off.
LED on
(1)
(2)