Franke Kaffeemaschinen AG
TD-100470.doc 12 / 32
1.5 Diagnostics
1.5.1 Coffee machine
This function allows you to conduct diagnostic tests on the coffee machine
1.5.2 MDB
This function allows you to view the MDB information.
Status:
Inactive à connection > MDB device not present or not found
Identified à a device identified itself
Disabled à the reader is not yet activated (>>red LED?)
Enabled à the reader is ready for cards, U-keys etc.
Ready à a card or U-key is in the reader
In the case of Ready additional information is shown alternatingly on the display.
Display Z2:
Ready mX rX dX
| | |
| | --- Number of decimal places
| ------ Revalue-capable reader (value increase) Yes = 1, No = 0
---------- MultiVend capable (multiple sale) Yes = 1, No = 0
1.6 CC-Simulation
1.6.1 Adjust
Here you can simulate the Adjust card and all menu accesses of this card.
Warning:
It is not possible to delete cards in a simulated menu.
1.6.2 Load
Here the Load card and all menu accesses of this card can be simulated.
Warning:
It is not possible to delete cards in a simulated menu.
The Load (direct) function can only be carried out directly with a Load card.