Franke Kaffeemaschinen AG
TD-100470.doc 24 / 32
77 EEPROM ERROR Writing error. There was an inconsistency while
reading back. Can be deleted by restarting.
80 UART 0 (X11) Interface 0: Initialisation error,
restart machine.
81 UART 0 (X11) Interface 0: Send memory overflow,
restart machine.
82 UART 0 (X11) Interface 0: Framing error,
restart machine.
83 UART 0 (X11) Interface 0: Parity error,
restart machine.
84 UART 0 (X11) Interface 0: Receive memory overflow,
restart machine.
90 UART 1 (X10) Interface 1: Initialisation error,
restart machine.
91 UART 1 (X10) Interface 1: Send memory overflow.
Restart machine.
92 UART 1 (X10) Interface 1: Framing error.
Restart machine.
93 UART 1 (X10) Interface 1: Parity error.
Restart machine.
94 UART 1 (X10) Interface 1: Receive memory overflow.
Restart machine.
100 E100 MDB Error Cashless: the sale was denied.
The medium may have been removed too early.
101 E101 MDB Error Cashless: crediting to MDB medium was denied. The
medium may have been removed too early.
102 E102 MDB Error Coin changer: a coin was accepted but not correctly
recognised.
104 E104 MDB Error Coin changer: a sensor of a coin tube may be faulty.