149
EN
Technical data
Special voltages
NOTE!
An inadequately dimensioned electrical installation can cause serious damage.
The mains cable and its fuse must be dimensioned accordingly.
The technical data shown on the rating plate applies.
MagicWave 190
MW 190 MW 190 MV
Mains voltage U
1
1 x 230 V 1 x 120 / 230 V
Mains voltage tolerance ± 15% ± 15%
Grid frequency 50/60 Hz 50/60 Hz
Mains fuse protection (slow-blow) 16 A 16 A (U
1
= 230 V)
20 A (U
1
= 120 V)
Mains connection
1)
Z
max
on PCC
3)
= 315 mOhm
Z
max
on PCC
3)
= 315 mOhm
Cos phi 0.99 0.99
Primary circuit S1max (at 100% D.C.
2)
)
TIG 2.7 kVA 2.7 kVA (U
1
= 230 V)
1.84 kVA (U
1
= 120 V)
Electrode 3.55 kVA 3.55 kVA (U
1
= 230 V)
1.94 kVA (U
1
= 120 V)
Welding current range
TIG 3 - 190 A 3 - 190 A
Electrode 10 - 170 A 10 - 170 A
Welding current at
10 min/40 °C (104 °F) 35% D.C.
2)
190 A
4)
170 A
5)
190 A
4)
(U
1
= 230 V)
150 A
4)
(U
1
= 120 V)
170 A
5)
(U
1
= 230 V)
100 A
5)
(U
1
= 120 V)
10 min/40 °C (104 °F) 60% D.C.
2)
160 A
4)
140 A
5)
160 A
4)
(U
1
= 230 V)
120 A
4)
(U
1
= 120 V)
140 A
5)
(U
1
= 230 V)
80 A
5)
(U
1
= 120 V)
10 min/40 °C (104 °F) 100% D.C.
2)
140 A
4)
120 A
5)
140 A
4)
(U
1
= 230 V)
100 A
4)
(U
1
= 120 V)
120 A
5)
(U
1
= 230 V)
70 A
5)
(U
1
= 120 V)
Open circuit voltage 100 V 100 V
Working voltage
TIG 10.1 - 17.6 V 10.1 - 17.6 V
Electrode 20.4 - 26.8 V 20.4 - 26.8 V
Striking voltage (U
p
) 9.6 kV 9.6 kV
The arc striking voltage is suitable for manual operation.
Degree of protection IP 23 IP 23
Type of cooling AF AF