141
EN
Troubleshooting
General The digital power sources are equipped with an intelligent safety system. This means that
apart from the fuse for the coolant pump, it has been possible to dispense with fuses en-
tirely. After a possible malfunction or error has been remedied, the power source can be
put back into normal operation again without any fuses having to be replaced.
Safety
WARNING!
Work that is carried out incorrectly may result in serious injury or damage to prop-
erty.
► All the work described below must only be carried out by trained and qualified person-
nel.
► Do not carry out any of the work described below until you have fully read and under-
stood this document.
► Do not carry out any of the work described below until you have fully read and under-
stood all of the documents relating to the system components, in particular the safety
rules.
WARNING!
An electric shock can be fatal.
Before starting the work described below:
► Turn the power source mains switch to the "O" position
► Disconnect the power source from the grid
► Ensure that the power source remains disconnected from the mains until all work has
been completed
► After opening the device, use a suitable measuring instrument to check that electrically
charged components (e.g. capacitors) have been discharged.
WARNING!
An inadequate ground conductor connection can cause serious injury or damage.
The housing screws provide a suitable ground conductor connection for earthing the hous-
ing.
► The housing screws must never be replaced with different screws unless a reliable
ground conductor connection is established.
Power source -
troubleshooting
Power source does not function
Mains switch is on, but indicators are not lit up
Cause: There is a break in the mains lead; the mains plug is not plugged in
Remedy: Check the mains lead, ensure that the mains plug is plugged in
Cause: Mains socket or mains plug faulty
Remedy: Replace faulty parts
Cause: Mains fuse protection
Remedy: Change the mains fuse protection