The following figures show the connection of the mini SAS HD cable between enclosures connecting
the controller enclosure to drive enclosure 1 and connecting drive enclosure 1 to drive enclosure 2.
โข When only one controller is installed
Drive enclosure 2
Drive enclosure 1
Controller enclosure
โข When two controllers are installed
Drive enclosure 2
Drive enclosure 1
Controller enclosure
(2) Attach the destination labels to the connectors of the mini SAS HD cables between enclosures.
"Controller number" or "Drive enclosure number - IOM number" is printed on the destination labels
in the "Connection origin DI port g Connection destination DI port" format. The "n" or "l" symbol is
also printed on the destination labels.
Carefully check the connection origin and connection destination, and then attach the destination
labels.
C M 0 0
DE01 0
IOM (I/O module) number
Drive enclosure number
CM (controller) number
4. Connecting Cables
Drive Enclosure Connection