EasyManua.ls Logo

GE Hydran 201i - Page 224

GE Hydran 201i
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MA-033 Rev. 14.0, 12-Nov-18
Hydran* 201i Instruction Manual
Page 224
Terminal
Description
From (Internal)
To (External)
Comments
15
16
Serial data(-),
I/O unit No. 3
J13-3, supervisory
link connector No. 3
Isolated RS-
485
transceiver
Must be
connected
to H201Ti
17
Serial data(+),
I/O unit No. 3
J13-4, supervisory
link connector No. 3
18
Loop supply(-),
input
J13-2, supervisory
link connector No. 3
Isolated
+5Vdc
regulator
input
Isolated
supply built
into
H201Ci
19
Loop supply(+),
input
J13-1, supervisory
link connector No. 3
20
Cable shield
Chassis
Supervisory
link cable
shield of
unit No. 3
Direct
ground
connection
21
Serial data(-),
I/O RS-485 LAN
J11-3, RS-485 LAN
connector
Isolated RS-
485
transceiver
Must be
connected
to other
H201Ci-C
or H201Ci-
1
22
Serial data(+),
I/O RS-485 LAN
J11-4, RS-485 LAN
connector
23
RS-485 LAN
ground
J11-2, RS-485 LAN
connector
Isolated
+5Vdc
regulator
input
Direct
ground
connection
24
Cable shield
J11-1, RS-485 LAN
connector
25
Not used
26
27
28
29
Serial data(-),
I/O unit No. 2
J12-3, supervisory
link connector No. 2
Isolated
RS485
transceiver
Must be
connected
to H201Ti
30
Serial data(+),
I/O unit No. 2
J12-4, supervisory
link connector No. 2
31
Loop supply(-),
input
J12-2, supervisory
link connector No. 2
Isolated
+5Vdc
Isolated
supply built

Table of Contents