EasyManua.ls Logo

HEIDENHAIN ITNC 530 - FN 20: WAIT FOR: NC and PLC synchronization

HEIDENHAIN ITNC 530
745 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HEIDENHAIN iTNC 530 347
9.8 Additional functions
FN 20: WAIT FOR: NC and PLC synchronization
With the FN 20: WAIT FOR function you can synchronize the NC and
PLC during a program run. The NC stops machining until the condition
that you have programmed in the FN 20 block is fulfilled. The TNC can
check the following PLC operands:
This function may only be used with the permission of
your machine tool builder.
PLC
operand
Short
designation
Address range
Markers M 0 to 4999
Entrance I 0 to 31, 128 to 152
64 to 126 (first PL 401 B)
192 to 254 (second PL 401 B)
Output O 0 to 30
32 to 62 (first PL 401 B)
64 to 94 (second PL 401 B)
Counter C 48 to 79
Timers T 0 to 95
Byte B 0 to 4095
Word W 0 to 2047
Double
word
D 2048 to 4095
In an FN20 block you can define a condition with a
maximum length of 128 characters.