4.
Align the two holes to the mounng plate with the drilled
holes.
5.
Fix and fasten the screws in the sockets on the wall or other
surface.
6.
Remove the two screws at the
boom of the device.
7.
Align the terminal with the mounng plate and buckle them
together.
8.
Use a hex wrench to fasten the two screws at the boom.
Note
•
The installaon height here is the recommended height. You
can change it according to your actual needs.
•
For easy installaon, drill holes on mounng surface
according to the supplied mounng template.
Figure 5-5 Installaon without Gang Box Diagram
6 Wiring
You can connect the RS-485 terminal with the RS-485 card reader,
connect the DOOR terminal with the door lock, connect the
BUT/GND terminal with the exit
buon, connect the ALARM OUT/
ALRM IN terminal with the alarm output/input devices, and
connect the WIEGAND terminal with the Wiegand card reader or
the access controller. You can also connect the DS_IN can with the
power supply.
If connect the WIEGAND terminal with the access controller, the
face
recognion terminal can transmit the authencaon
informaon to the access controller and the access controller can
judge whether to open the door or not.
Note
•
If you use 1.0 mm cables, you should use a 12V switched-mode
power supply. And the distance between the power supply and
the device should be no more than 20 m.
•
If you use 1.5 mm cables, you should use a 12V switched-mode
power supply. And the distance between the power supply and
the device should be no more than 30 m.
•
If you use 2.0 mm cables, you should use a 12V switched-mode
power supply. And the distance between the power supply and
the device should be no more than 40 m.
6.1 Wire Device
You can connect the terminal with peripherals.
The wiring diagram without secure door control unit is as follows.
10