5.
Enable the event so that when the event is detected, en event
will be sent to the client and the linkage acons will be
triggered.
6.
Oponal: Click Copy to... to copy the event sengs to other
access control device, alarm input, door/elevator, or card
reader.
9.5.2 Congure Device Acons for Access Event
You can set the access control device's linkage acons for the
access control device's triggered event. When the event is
triggered, it can trigger the alarm output, host buzzer, and other
acons on the same device.
Steps
Note
It should be supported by the device.
1.
Click Access Control Linkage
Conguraon .
2.
Select the access control device from the list on the le.
3.
Click Add buon to add a new linkage.
4.
Select the event source as Event Linkage.
5.
select the event type and detailed event to set the linkage.
6.
In the Linkage Target area, set the property target to enable
this
acon.
Buzzer on Controller
The audible warning of access control device will be
triggered.
Capture
The real-me capture will be triggered.
Recording
The recording will be triggered.
Note
The device should support recording.
Buzzer on Reader
The audible warning of card reader will be triggered.
Alarm Output
The alarm output will be triggered for
nocaon.
Alarm Input
Arm or disarm the alarm input.
Note
The device should support alarm input funcon.
Access Point
The door status of open, close, remain open, and remain
close will be triggered.
Note
The target door and the source door cannot be the same
one.
Audio Play
71