Page #68 background imageLoading...
Page #68 background image
5.
Enter the maximum interval when entering password.
6.
Add an authencaon group for the selected access control
point.
1) Click Add on the Authencaon Groups panel.
2) Select a congured template as the authencaon template
from the drop-down list.
Note
For seng the template, refer to Congure Schedule and
Template.
3) Select the authencaon type as Local Authencaon,
Local Authencaon and Remotely Open Door, or Local
Authencaon and Super Password from the drop-down
list.
Local Authencaon
Authencaon by the access control device.
Local Authencaon and Remotely Open Door
Authencaon by the access control device and by the
client. When the person swipes the card on the device, a
window will pop up. You can unlock the door via the
client.
Figure 9-1 Remotely Open Door
Note
You can check Oine Authencaon to enable the super
password authencaon when the access control device
is disconnected with the client.
Local Authencaon and Super Password
Authencaon by the access control device and by the
super password.
4) Select the added person/card group in the
le list below and
it will be added to the Selected list on the right as the
authencaon group.
5) Click the added authencaon group in the right list to set
authencaon mes in the Auth Times column.
Note
The authencaon mes should be larger than 0 and
smaller than the added personnel quanty in the
personnel group.
The maximum value of authencaon mes is 16.
6) Click Save.
59

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-K1T605 Series and is the answer not in the manual?

HIKVISION DS-K1T605 Series Specifications

General IconGeneral
BrandHIKVISION
ModelDS-K1T605 Series
CategoryIP Access Controllers
LanguageEnglish

Related product manuals