Replacing drives 4–9
Hitachi Unified Storage Hardware Service Guide
NOTE 1: User data cannot be backed up when a drive to be replaced is
blocked or when the drive belongs to a RAID Group that contains a blocked
drive.
NOTE 2: The red ALM LED on the drive goes OFF within about five
minutes after the drive is inserted into the drive slot on the storage system.
If the red ALM LED does not go OFF, remove the inserted drive from the
storage system, wait at least 30 seconds, and then insert it again.
NOTE 3: If the orange WARNNG LED is blinking slowly, visit the HDS
Support Portal at portal.hds.com.
NOTE 4: If the green READY LED on the front of the Controller Box is
blinking quickly for 30-to-50 minutes, 40-to-60 minutes for the CBL
Controller Box, or 80-to-180 minutes when the DBW is connected to the
CBL, wait for the LED to stop blinking before replacing drives.