6.2.14 Ink Heating Unit Temperature Sensor Fault
- On detecting this fault, the IJ printer automatically sets the “Ink temperature
correction” to (disable).
“System environment setup: Ink temperature correction (enable) (disable)”
After getting rid of the fault, reset the Ink temperature correction to (enable).
“System environment setup: Ink temperature correction (disable) (enable)”
- In the condition of the “Ink temperature correction (disable), ” the “Ink Temperature
Correction Notice” message appears each time the power is turned on.
(See “1.6 Heating of Ink” in the Instruction manual”.)
Ink Heating Unit
Temperature Sensor
Fault
Disconnect the EZJ125 board
CN7 connector and reconnect it.
Replace the heating unit.
Replace the EZJ125 board.
▪ From the maintenance screen, place
the heating unit in the operating mode. *)
▪ Restart the IJ printer.
Replace the EZJ126 board.
▪ From the maintenance screen, place
the heating unit in the operating mode. *)
▪ Restart the IJ printer.
▪ From the maintenance screen, place
the heating unit in the operating mode. *)
▪ Restart the IJ printer.
*) Refer to the following caution.