2-1
2. Maintenance work
A screen for use in the maintenance work by a service personnel is described.
2.1 Setting of service personnel maintenance mode
● Set service personnel maintenance mode to perform maintenance work by service
personnel such as system environment setup.
Features of service personnel maintenance mode (differences with user maintenance mode)
The second page of the maintenance menu can be displayed.
Can boot system environment setup; upgrade setup, download,
option setup, and various system initialization functions.
The ink coefficient can be changed.
The cumulative operating time can be changed.
Displays “heating unit temperature” and “ink temperature”.
Displays “excitation voltage reading”, “ambient temperature”
and “ink pressure”.
5 Fault/warning history Displays Clear; can clear Fault/warning history.
6
Can boot Viscometer calibration function.
7
Parts usage time
management
The time of the pump and the solenoid valves can be changed.
8
Circulation system
environment setup
Sets whether or not to display the message informing the user
that “ink concentration control has been set to disable” when
the power is turned on if “ink concentration control” is set to
9
Software management
(View software version)
Displays version of ink management table.
Displays version of booting system (program loader) in
parentheses next to the version display.
Solenoid valve / pump
test
Multiple operations of the solenoid valve can be carried out
simultaneously.
11 User environment setup
Displays “Product Speed Matching Error”, “Arabic pattern
variation” and “Minimum character height value”.
Displays “Status Color” and “Standby/Ready Change Button”.
13 Login management Displays Clear; can clear login history.
14
Backs up logging data that records history of operation status
(including text file).
Can copy unit-specific data (environment setup values,
operation time, etc.) to IJP if serial number is the same as
New language data to save are stored and the input mode
can be selected.
17 Fault The fault, No ink drop charge, does not invoke ink stoppage.
18
Periodic replacement
parts mgmt.
The exchange cycle of the pump and solenoid valve can be
changed.
● A “USB memory containing system data” is needed to perform the following maintenance
work by service personnel.
Functions requiring USB memory containing system data
Required when changing the nozzle diameter setup. The
USB memory is not required for other setting.
Required when updating program.
Required when new language data to save are stored.
The USB memory is not required for other setting.
Note: Use a USB memory that complies with USB 2.0/1.1 interface and
FAT16 or FAT32 file system.