2.7 Circulation system environment setup
●Select whether or not the ink concentration is controlled based on results of the viscosity
measurement.
●Perform these settings at “Stop” state.
Setting items of Circulation system environment setup screen
Ink concentration control
Disable
The ink concentration is controlled by the
dot count control without measurement of
the ink viscosity.
(Dot count control: Amou
used for printing and vaporized makeup are
The ink concentration is controlled based on
results of the viscosity measurement.
carefully washing.
Reference of (2.19 Careful Cleaning Setup)
Automatic stir out of
operation
It perform the stirring in the device every 24
hours
Selects enable/disable for Solvent recovery
1 Press Circulation environment setup Start/Continue on the second page of
the circulation control menu of maintenance.
The Circulation system environment setup screen is then displayed.
*Caution: 1. Under ordinary circumstances, the default setting of “ink concentration control”
is “Enable.”
2. ”Enable” can not be selected for some inks.
In this case, ink concentration is not controlled by the viscometer,
but is controlled by dot count.
Back
Ink type 001 (1067K )
Ink concentration control
Circulation env. setup
HOME
Automatic stir out of operation
Careful-Cleaning Stop