2-51
2.20 Logging data
- Log the operating conditions to investigate the fault and warning condition.
- Log files are copied to the below holder when backup function is performed in the Service
personnel maintenance mode.
List of Log files
When Fault or Warning happens.
replenished automatically.
3 INKVISCO.TXT Viscosity control When ink and makeup are
replenished automatically.
4 SEQUENCE.TXT Circulation system control When circulation syste
m control
sequence is done.
- Up to 480 logging data can be recorded. If the number of logging data exceeds 480, the oldest
data is erased.
1
Contents of each log file
The following examples show the image of the logging data (text file) is pasted to Microsoft Excel
format.
(1) Fault and warning log (ALARM.TXT)
[Example]
- Code: Log management code of each Fault and Warning.
(Refer to the 2.13 Fault / Warning log management code)
- Info1 to 4: Internal management code to specify the cause of alarm
№ Date Time Code Message
Info1 Info2 Info3 Info4
1 2011/7/7 7:05:29 22 Internal Communication Error S 0x0004 0x0000 0
0
2 2011/7/7 7:06:56 176 Viscometer not Calibrated 0x0000
0x0000 0 0
3 2011/7/7 8:06:56 88 Battery Low 0x0000 0x0000 0 0
4 2011/7/7 9:07:45 17 Heating Unit Sensor Fault 0x0002 0x0000 32 12
5 2011/7/7 10:12:04 1 Ink Low Fault 0x0000 0x0000 0 0
6 2011/7/7 11:37:20 2 Main Ink Tank Too Full 0x0000 0x0000 0 0
7 2011/7/7 12:07:22 50 Cover Open 0x0000 0x0000 0 0
8 2011/7/7 12:14:45 209 Storage Media Error 0x0000 0x0000 0 0