3-43
3.3.14 Multiple Power Supply
[Function]
- AC input: AC100 ~ 240V (50/60Hz)
DC output: +3.4V, +5.1V, +12V, -12V, +24V
[Note at the replacement]
- In a few seconds after turned off the power, residual voltage is remaining on the parts
of multiple power supply.
- When replacing the multiple power supply, turn off the power and wait for more than
10 seconds, pull the plug out of socket, and then access the multiple power supply.
[Replacement procedure of multiple power supply]
(1) Turn off the main power and wait for more than 10 seconds.
Then pull the plug out of socket.
(2) Remove the fixing screws (6 positions) and remove the side cover.
(It is not necessary to remove the inlet base and inlet cover.)
cover which has a portion where AC power is applied.
The multiple power supply has a portion where high voltage is applied. In order to avoid an
electric shock, turn off the power and wait for more than 10 seconds, pull the plug out of