4-10 
4.3 Pressure Reducing Valve Replacement Procedure 
 
1 Perform “Pressure relief”. 
 
2 Perform the procedures described in “4.1.2 Access to the parts on the front side of the 
equipment”. 
 
3  Remove  Fastening screw  M4x12  (2 positions: upper right and lower left of Pressure 
reducing valve) and Pressure reducing valve itself. 
And remove the O-ring S-4 (1 piece). 
 "Caution" : Put wiping paper under Pressure reducing valve to avoid dripping on the 
floor, etc. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
4 Prepare a new Pressure reducing valve and a new O-ring (1 piece). 
[Caution] Make sure to use O-ring S-4 (1 piece). 
 
 
 
 
 
 
 
5 Wet O-ring S-4 with makeup and put it on the joint of the new Pressure reducing valve. 
 
6 Attach the new Pressure reducing valve in reverse order of the procedures above. 
 
 [Caution] When attaching the Pressure reducing valve, make sure O-ring S-4 is kept in 
place and it does not fall off. 
 Pay attention to the orientation of the Pressure reducing valve joint. 
 [“AI” mark shall look Down.] 
 
 
7 Perform “Ink Replenishment” and adjust the pressure. Make sure that there is no ink leak.