6-30
6.3.2 Barcode Short On Numbers
Fixed character number
When country code is input
on edit message screen
When country code is input
on print format screen
EAN-13
12
10
EAN-8
7
5
UPC-A
11
UPC-E
8
GS-1
data bar
Limited:13
Omnidirectional:13
Refer to the Instruction Manual, ”4.13.3 Set various printing”.
6.3.3 Shutdown Fault
Barcode Short On Numbers
Input the fixed number of character for EAN-13,
EAN-8, UPC-A, UPC-E
Resume the operation.
Shutdown Fault
Disconnect the EZJ113
board CN4 connector and
EZJ126 CN20 connector
and reconnect them.
Replace the EZJ113 board.
No
Resume the
operation.
Is the
fault issued
again?
Yes
Replace the EZJ126 board.
Is the
fault issued
again?
Yes
No