3-33 
          [Replacement procedures of EZJ113 board] 
(1)  Turn off the power and wait for more than 10 seconds. Then pull the plug out of the 
wall outlet. 
  
              (2) Remove the fixing screws (4 locations) , remove the side cover 
                    and remove the ground wire. 
                    (It is not necessary to remove the inlet base and inlet cover.) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
              (3) Remove the connectors (CN1, 2, 3, 4) and replace EZJ113 board, with a new one. 
                    (Three fixing spacers and one fixing screw.) 
              (4) Insert the connectors of CN1, CN2, CN3 and CN4 in place. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
              (5) Place the ground wire terminal around the connecting position, then close the side 
                    cover. When closing the cover, be sure not to pinch the wires. 
              (6) Be sure to connect the ground wire terminal to the ground wire connecting position.