4-4 
4.1.2 Access to the parts on the front side of the equipment 
 
1 Remove the Inner cover (T). 
. 
 
2 Remove the fixing screws (2 pieces) and draw the reservoir unit out to the front   
    halfway by supporting “a” part (4 places) with both hands. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3 Remove the tubes and cables from the clamp. 
 
 
 
 
 
 
 
 
 
 
 
4 Pull the reservoir unit out further and put it on the maintenance cover. 
 
  [CAUTION]   
Carefully mount the Reservoir unit back 
to its place so that the piping tube of 
the recovery filter is not pinched. 
 
After performing the task of pulling the 
Reservoir unit, please make sure that the 
level sensor is functioning normally. 
【 CAUTION】  
Please  do  not  remove  the 
lock pin guard. 
When it is removed by any 
chance,  please  return  it  to 
the original position.