EasyManua.ls Logo

Hitachi UX Twin Nozzle - Pressure Reducing Valve Replacement Procedure

Hitachi UX Twin Nozzle
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-12
4.3 Pressure Reducing Valve Replacement Procedure
1 Perform Pressure relief.
2 Perform the procedures described in 4.1.2 Access to the parts on the front side of the
equipment.
3 Remove Fastening screw M4x12 (2 positions: upper right and lower left of Pressure
reducing valve) and Pressure reducing valve itself.
And remove the O-ring S-4-E-227 (1 piece).
[Caution] Put wiping paper under Pressure reducing valve to avoid dripping on the floor, etc.
4 Prepare a new Pressure reducing valve and a new O-ring S-4-E-227 (1 piece).
[Caution] Make sure to use O-ring S-4-E-227 (1 piece).
5 Wet O-ring S-4-E-227 with makeup and put it on the joint of the new Pressure reducing
valve.
6 Attach the new Pressure reducing valve in reverse order of the procedures above.
[Caution] When attaching the Pressure reducing valve, make sure O-ring S-4-E-227 is
kept in place and it does not fall off.
Pay attention to the orientation of the Pressure reducing valve joint.
[AI mark shall look Down.]
7 Perform Ink Replenishment and adjust the pressure. Make sure that there is no ink leak.
O-ring S-4
O-ring 4.7
6.5
7.7
Pressure reducing valve
Fixing screw M4X12

Table of Contents

Other manuals for Hitachi UX Twin Nozzle

Related product manuals