    6.4 Warning conditions (printing continuously performed) 
 6.4.1    Excitation V-ref. Review, Excitation V-ref. Review 2 
 
 
 
 
 
 
 
 
 6.4.2 Viscosity Reading Instability 
 
 
(*1): The Viscosity measurement during 
IJP  operation  is  conducted  every 
15minutes  just  before  the  ink 
replenishment. When the viscosity 
values  measured  are  instable,  the 
ink  is  replenished  by  dot  counts 
but  NOT  by  the  viscosity 
measurement  result.  If  this  ink 
replenishment  by  dot  counts  is 
made  three  times  in  a  row,  the 
warning  of  “Viscosity  Reading 
Instability” will be indicated. After 
this  warning  indication,  the 
viscosity  measurement  is 
conducted  every  15minutes 
however  the  ink  is  replenished  by 
dot  counts  until  the  ink  viscosity 
returns to a stable condition. 
 
(*2):  When  you  disassemble  and  clean 
or  replace  the  Viscometer,  refer 
to  “4.  12  Troubleshooting  when 
Fault Occurs in Viscometer”.