3-19 
 [Registerable languages based on the state of Language key] 
- When you want to confirm the state of Language key, refer to page 2 of “Unit information” screen. 
- Contact your local distributor for the details of registerable languages. 
Information on 
page 2 of   
“Unit 
information”  
screen   
Language key is NOT installed or broken. 
The  language  can  be  registered  in 
the area supported. 
Unit serial number and the unit serial number   
registered in Language key are different. 
Language key “Type A” all languages other than 
Japanese is installed. 
All languages can be registered 
except Japanese. 
Language key “Type B” all languages is installed. 
All languages can be registered 
including Japanese. 
 
Indirectly-exported machine   
(Corresponding to countries other than Japan) 
   
3.3.5 EZJ125 board (Nozzle1 drive board) 
 
[Function] 
- Control of nozzle (charging voltage control, excitation voltage, APH detection, PTC 
control etc.) is performed. 
 
 
          [Setting of switch/check point/LED display etc.] 
  - Setting of switch 
Detection signal of charged amount of ink drop 
Character signal which charged ink drop 
Sine wave signal applied to a nozzle 
APH signal for checking with eyes 
With respect to the 
excitation adjustment, 
refer to “2.3.1 Excitation 
adjustment”. 
 
With respect to the 
charging voltage 
confirmation, refer to 
“2.3.2 Charging voltage 
confirmation”.