4-23
4.7 Circulation Unit Replacement Procedure
1 Perform “Ink drainage” and then “Pressure relief”.
2 Turn off the power supply.
3 Perform “4.1.2 Access to the parts on the front side of the equipment” and draw out the
reservoir unit.
4 Perform 4.1.3 Access to the parts on the rear side of the equipment (1) Access method
from the front and open the unit door.
[Caution] Be careful not to catch the tubes.
5 Remove the tubes (15 positions*) that are connected to the circulation unit.
[Caution] Be careful about ink dripping.
6 Remove the wire harness from the clamps (6 positions).