3-37 
 
          [Connection to the external connection terminal block (EZJ119A -TB2)] 
 
                      Terminal specification: M4 
 
 
            [Setting of switch 3] 
  The ready output selector switch (SW3) is the switch which determins to enable or 
    disable of Ready signal output. 
   
When this setting is employed, Ready output signal is enabled. The 
path between the TB2 terminals opens or closes depending 
on whether IJ printer state is Ready or not. 
 
 
 
 
 
When NC contact (break contact) is used, Ready output signal is 
disabled. The path between the TB2 terminals opens as shown in 
the table below regardless whether IJ printer state is Ready or not. 
 
 
 
 
When NO contact (make contact) is used, Ready output signal is 
disabled. The path between TB2 terminals 1 and 3 opens and the 
path between TB2 terminals 2 and 3 closes as shown in the table 
below regardless whether IJ printer state is Ready or not.