3-58
●Connector numbers and Identifying method of Harness.
Position of connector of No.1 to No.17
No. Name Harness mark band No. Board Connector No. Identifying method
1
Fan harness none EZJ133 CN29
Misinstallation cannot be made by
the number of pins
4
none EZJ125 CN7
5
[2] EZJ133 CN38
6
[3] EZJ125 CN3
7
[3][3] EZJ134 CN3
8
[5] EZJ125 CN5
9
[5][5] EZJ134 CN1
10
[2] EZJ125 CN2
11
[2][2] EZJ133 CN36
12
15
EZJ134 CN2
16
EZJ139 CN1
17
EZJ139 CN3
Multi-power supply harness,
primary side-16pins
Multi-power supply harness,
secondary side-16pins
Deflection voltage harness
High voltage power supply
harness(10pins)
High voltage power supply
harness(2pins)
View inside after EZJ134 board fixing metal is removed.
Cases of wrong connection
(Refer to the table of
“Connector numbers and
Identifying method of
Harness”)
Symptom caused by wrong connection
Screen display is NOT lit up after main power is turned ON.
Warning of “Ambient temperature Sensor Fault” occurs after main power is
turned ON.
Print positions of nozzle1 and 2 are inverted against the setting of print format.
Shape of ink drop does NOT change even though the value of Auto-phase gain in
“Auto-phase gain adjustment” is changed for the object nozzle.
Printing becomes disordered. APH wave form does NOT change even though the
value of Auto-phase gain is changed.
Charge or deflection-related faults (NO charge, charging too low or too high,
leaking deflection voltage) occurs even though the gutter and charging deflecting
electrode of object nozzle are NOT dirty by ink.
※Note that the wrong connection is NOT allowed by the length of the harness for Connector No.12-No.17