4-61
10 Remove the piping connections with the printhead (3 locations) at the back of Circulation unit.
11 Rotate the Head H Clamp assembly by 45 degrees and pull the Head H Clamp
Assembly out.
12 Widen the Claws of Head H Clamp assembly and remove it from the harness of
the print head.
Head H Clamp assembly
Claws
Head H Clamp
assembly
Makeup line
(Mark: RR)
Circulation line
(Mark: JJ)
Circulation line
(Mark: HH)