6-29
6.2.14b (N2)Ink Heating Unit Temperature Sensor Fault
- On detecting this fault, the IJ printer automatically sets the Ink temperature
correction to (disable).
System environment setup: Ink temperature correction (enable) (disable)
After getting rid of the fault, reset the Ink temperature correction to (enable).
System environment setup: Ink temperature correction (disable) (enable)
- In the condition of the Ink temperature correction (disable), the Ink Temperature
Correction Notice message appears each time the power is turned on.
(See 1.6 Heating of Ink in the Instruction manual.)
Caution
!
(*1): When you replace Heating unit, refer to “5.6 Heating unit
replacement”.
(*2): When you replace EZJ133 board, refer to
[Replacement
procedures of EZJ133 board]
in
3.3.1 EZJ133 board
(MPU board)”.
[Caution]
Be sure to check that there is no wrong connection of harnesses
by referring to
[Connector numbers and Identifying method of
harnesses]
in
“3.3.20 Electrical Connection Diagram”.
(N2)Ink Heating Unit
Temperature Sensor
Fault
Disconnect the EZJ133 board
CN38 connector and reconnect it.
Replace the heating unit.*1
Replace the EZJ133 board*2.
Resume the
operation.
Yes
No
Clear the fault.
From the maintenance screen, place
the heating unit in the operating mode. *)
Restart the IJ printer.
Does the fault recur?
Yes
No
Does the fault recur?
Clear the fault.
From the maintenance screen, place
the heating unit in the operating mode. *)
Restart the IJ printer.
*) Refer to the following caution.
*) Refer to the
following caution.