6-36
6.2.22 Inside Temperature Sensor Fault
(*1): When you replace thermistor, refer to “4.12.5 Replacing thermistor”
(*2): When you replace EZJ133 board, refer to
[Replacement procedures of EZJ133 board]
in
3.3.1 EZJ133
board (MPU board)”.
[Caution]
Be sure to check that there is no wrong connection of harnesses by referring to
[Connector numbers and
Identifying method of harnesses]
in
“3.3.20 Electrical Connection Diagram”.
Viscometer Ink
Temperature Sensor
Fault
Replace the thermistor of Viscometer*1.
Replace the EZJ133 board*2.
Resume the
operation.
Does the fault recur?
Yes
No
Does the fault recur?
Yes
No
Disconnect and reconnect the following
connectors.
EZJ133: CN13
EZJ138: CN1, CN4
Thermistor relay harness connector