6-49
6.3.2 Barcode Short On Numbers
Fixed character number
When country code is input
on edit message screen
When country code is input
on print format screen
EAN-13
12
10
EAN-8
7
5
UPC-A
11
UPC-E
8
GS-1
data bar
Limited:13
Omnidirectional:13
Refer to the Instruction Manual, ”4.13.3 Set various printing”.
6.3.3 Shutdown Fault
Shutdown Fault
Disconnect the EZJ113 board CN4 connector and
EZJ133 CN20 connector and reconnect them.
Replace the EZJ113 board.*1.
No
Resume the
operation.
Is the fault issued
again?
Yes
Replace the EZJ133.*3
Is the fault issued
again?
Yes
No
Disconnect the EZJ139 board CN4 connector and
EZJ133 board CN34 connector and reconnect them.
Replace the EZJ139 board.*2
No
No
(*1): When you replace EZJ113 board, refer to
[Replacement procedures of EZJ113 board] in
“3.3.9 EZJ113 board (Power relay board 1)”.
(*2): When you replace EZJ139 board, refer to
[Replacement procedures of EZJ139 board] in
“3.3.10 EZJ139 board (Power relay board 2)”.
(*3): When you replace EZJ133 board, refer to
[Replacement procedures of EZJ133 board] in
3.3.1 EZJ133 board (MPU board)”.
[Caution]
Be sure to check that there is no wrong connection
of harnesses by referring to [Connector numbers and
Identifying method of harnesses] in “3.3.20
Electrical Connection Diagram”.