6-56
6.3.13 Internal Communication Error C / T / M
Reset the system by rescue software.
Is the EZJ128 board CN1
connector disconnected or
in poor contact?
Is SOP05 used for
calling up print data?
Input the strobe signal with correct
timing of the SOP05 specification.
Internal Communication
Error C/M
The strobe input timing is
following the regulation?
Is the EZJ133 board CN1
connector disconnected or
in poor contact?
Disconnect the connector once.
And then reconnect it correctly.
Replace the EZJ128 board.*1
Replace the EZJ133 board *2.
Check IJ printer’s model, then
download the software again, which
corresponds to the IJ printer model.
Was software downloaded just
before this error occurred?
(*1): When you replace EZJ 128
board, refer to [Replacement
procedures of EZJ128 board]
in “3.2.1 EZJ128 board
(controller board)”.
(*2): When you replace EZJ133
board, refer to [Replacement
procedures of EZJ133 board]
in “3.3.1 EZJ133 board
(MPU board)”.
[Caution]
Be sure to check that there is no
wrong connection of harnesses by
referring to [Connector numbers
and Identifying method of
harnesses] in “3.3.20 Electrical
Connection Diagram”.