6-70
6.4.10 Ambient Temperature Too High / Too Low
Ambient temperature
Too High / Too Low
Does the IJ printer
temperature indication agree
with the ambient
temperature?
Is the EZJ133 board CN38
connector disconnected?
Replace the EZJ133 board.*1
Is the Ambient temperature
upper-/lower-limit value
erroneously set?
Properly set the Ambient
temperature upper-/lower-limit
value.
Use an air-conditioner or the like
to ensure that the IJ printer
ambient temperature is within
the operating temperature range.
Replace the print head.※3
Replace the Thermistor of head cable.*2
Replace the EZJ133 board *1.
(*1): When you replace EZJ133 board, refer to
[Replacement procedures of EZJ133 board] in
“3.3.1 EZJ133 board (MPU board)”.
(*2): When you replace Thermistor, refer to
“5.10 Thermistor replacement”.
[Caution]
Be sure to check that there is no wrong connection of
harnesses by referring to [Connector numbers and
Identifying method of harnesses] in “3.3.20 Electrical
Connection Diagram”.