6-73
6.4.12 Battery Low C
Battery Low C
Resume the
operation.
Is the EZJ128 board
CN8 connector
disconnected or in poor
contact?
Yes
No
Replace the battery of
EZJ128 board. *1
Yes
Replace the EZJ128 board.*2.
Does the fault recur?
No
(*1): When you replace the battery of EZJ128, refer to [Note at the replacement] in “3.2.2 Battery”.
(*2): When you replace EZJ 128 board, refer to [ Replacement procedures of EZJ128 board ] in “3.2.1 EZJ128 board
(controller board)”.
[Caution]
Be sure to check that there is no wrong connection of harnesses by referring to [Connector numbers and Identifying
method of harnesses] in “3.3.20 Electrical Connection Diagram”.
Remove the connector once and
reconnect it