6-75
6.4.13b (N2) Ink Pressure Low
(*1): When you replace pressure reducing valve,
refer to “4.3 Pressure Reducing Valve
Replacement Procedure”.
(*2): When you replace pressure sensor2, refer to
“4.6.2 Pressure Sensor (Nozzle 2) Replacement
Procedure”.
Can the pressure be adjusted by
the pressure reducing valve?
Adjust the pressure to
standard value
by the pressure reducing
valve.
Replace the pressure reducing valve.*1
Replace the pressure sensor2.*2
Can the pressure be adjusted by
the pressure reducing valve?
Can the pressure be adjusted by
the pressure reducing valve?
Replace or repair the troubled
solenoid.
Replace MGV filter in Nozzle2.
Replace or repair the troubled
solenoid.
Replace or repair the
supply pump.
Confirm the indicated value and standard value of ink
pressure in Nozzle2 on “Operation management” screen.
Is the difference of ±0.01MPa
or more in indicated value of
ink pressure between Nozzle1
and Nozzle2?
The indicated value of ink pressure
in Nozzle2 exceeds the lower limit?
(Standard value x 0.90 >Indicated value)
Does ink flow into main ink tank
when pumps MV1 & MV6 are
operated?