EasyManuals Logo

Hiwin E1 Series User Manual

Hiwin E1 Series
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #363 background imageLoading...
Page #363 background image
E1 Series Servo Drive User Manual Parameters
HIWIN MIKROSYSTEM CORP. 15-31
MD09UE01-1910
Pt No.
Pt480
Size 2
Setting
Range
0~10000 Default 10000
Name
Velocity limit during
force control (linear
servo motor)
Unit 1 mm/s
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt481
Size 2
Setting
Range
0~100 Default 0
Name
Polarity detection
loop gain
Unit Stiffness level
Applicable
Motor
All
Effective
Immediately
Category
Tuning
Reference
-
Pt No.
Pt483
Size 2
Setting
Range
0~800 Default 30
Name
Forward force limit
value for internal
force limit (linear
servo motor)
Unit 1% (rated force)
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt484
Size 2
Setting
Range
0~800 Default 30
Name
Reverse force limit
value for internal
force limit (linear
servo motor)
Unit 1% (rated force)
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt488
Size 2
Setting
Range
0~5000 Default 1000
Name
Waiting time for Hall
polarity detection
command
Unit 1 ms
Applicable
Motor
All
Effective
Immediately
Category
Tuning
Reference
-
Pt No.
Pt498
Size 2
Setting
Range
0~30 Default 30
Name
Allowable error
range for Hall
polarity detection
Unit 1 deg
Applicable
Motor
All
Effective
Immediately
Category
Tuning
Reference
-

Table of Contents

Other manuals for Hiwin E1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hiwin E1 Series and is the answer not in the manual?

Hiwin E1 Series Specifications

General IconGeneral
BrandHiwin
ModelE1 Series
CategoryServo Drives
LanguageEnglish

Related product manuals