E1 Series Servo Drive User Manual Parameters
HIWIN MIKROSYSTEM CORP. 15-43
MD09UE01-1910
Pt No.
Pt51B
Size 4
Setting
Range
0~1073741824 Default 1000
Name
Detection value for
overflow motor-load
position deviation
Unit 1 control unit
Applicable
Motor
Rotary
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt51E
Size 2
Setting
Range
10~100 Default 100
Name
Warning value for
overflow position
deviation
Unit 1%
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt520
Size 4
Setting
Range
1~1073741823 Default 5242880
Name
Alarm value for
overflow position
deviation (rotary
servo motor)
Unit 1 control unit
Applicable
Motor
Rotary servo motor
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt521
Size 4
Setting
Range
1~1073741823 Default 500000
Name
Alarm value for
overflow position
deviation (linear
servo motor)
Unit 1 control unit
Applicable
Motor
Linear servo motor
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt522
Size 4
Setting
Range
0~1073741824 Default 7
Name
Positioning
completion width
Unit 1 control unit
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt523
Size 4
Setting
Range
0~1000 Default 0
Name Debounce time Unit 1 ms
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-