EasyManuals Logo

Hiwin E1 Series User Manual

Hiwin E1 Series
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #375 background imageLoading...
Page #375 background image
E1 Series Servo Drive User Manual Parameters
HIWIN MIKROSYSTEM CORP. 15-43
MD09UE01-1910
Pt No.
Pt51B
Size 4
Setting
Range
0~1073741824 Default 1000
Name
Detection value for
overflow motor-load
position deviation
Unit 1 control unit
Applicable
Motor
Rotary
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt51E
Size 2
Setting
Range
10~100 Default 100
Name
Warning value for
overflow position
deviation
Unit 1%
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt520
Size 4
Setting
Range
1~1073741823 Default 5242880
Name
Alarm value for
overflow position
deviation (rotary
servo motor)
Unit 1 control unit
Applicable
Motor
Rotary servo motor
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt521
Size 4
Setting
Range
1~1073741823 Default 500000
Name
Alarm value for
overflow position
deviation (linear
servo motor)
Unit 1 control unit
Applicable
Motor
Linear servo motor
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt522
Size 4
Setting
Range
0~1073741824 Default 7
Name
Positioning
completion width
Unit 1 control unit
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt523
Size 4
Setting
Range
0~1000 Default 0
Name Debounce time Unit 1 ms
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-

Table of Contents

Other manuals for Hiwin E1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hiwin E1 Series and is the answer not in the manual?

Hiwin E1 Series Specifications

General IconGeneral
BrandHiwin
ModelE1 Series
CategoryServo Drives
LanguageEnglish

Related product manuals