IFP-75/IFP-75HV Installation/Operation Manual — P/N LS10147-001SK-E:D 06/25/2021 123
Receivers Compatible with the Control Panel Reporting
Manual release switch alarm
(Water Release Zone)
pi Exp. ID FA Point # FANNXXPPPP 1 110 Exp. ID Point #
Manual release switch alarm restore
(Water Release Zone)
pi Exp. ID FH Point # FHNNXXPPPP 3 110 Exp. ID Point #
Manual release switch disabled pi Exp. ID FB Point # FBNNXXPPPP 1 571 Exp. ID Point #
Manual release switch enabled pi Exp. ID FU Point # FUNNXXPPPP 3 571 Exp. ID Point #
Manual release switch trouble
(Water Release Zone)
pi Exp. ID FT Point # FTNNXXPPPP 1 373 Exp. ID Point #
Manual release switch trouble restore
(Water Release Zone)
pi Exp. ID FJ Point # FJNNXXPPPP 3 373 Exp. ID Point #
Notification output point disabled pi Exp. ID FB Point # FBNNXXPPPP 1 571 Exp. ID Point #
Notification output point enabled pi Exp. ID FU Point # FUNNXXPPPP 3 571 Exp. ID Point #
Notification output point trouble pi Exp. ID FT Point # FTNNXXPPPP 1 320 Exp. ID Point #
Notification output point trouble restore pi Exp. ID FJ Point # FJNNXXPPPP 3 320 Exp. ID Point #
Positive Alarm Sequence acknowledge
switch disabled
pi Exp. ID FB Point # FBNNXXPPPP 1 571 Exp. ID Point #
Positive Alarm Sequence acknowledge
switch enabled
pi Exp. ID FU Point # FUNNXXPPPP 3 571 Exp. ID Point #
Positive Alarm Sequence acknowledge
switch trouble
pi Exp. ID FT Point # FTNNXXPPPP 1 373 Exp. ID Point #
Positive Alarm Sequence acknowledge
switch trouble restore
pi Exp. ID FJ Point # FJNNXXPPPP 3 373 Exp. ID Point #
Status Point Trouble pi Exp. ID UT Point # UTNNXXPPPP 1 379 Exp. ID Point #
Status Point Trouble Restored pi Exp. ID UJ Point # UJNNXXPPPP 3 379 Exp. ID Point #
Status Point is Disabled pi Exp. ID UB Point # UBNNXXPPPP 1 580 Exp. ID Point #
Status Point is Enabled pi Exp. ID UU Point # UUNNXXPPPP 3 580 Exp. ID Point #
Supervisory/Tamper Alarm pi Exp. ID FS Point # FSNNXXPPPP 1 200 Exp. ID Point #
Supervisory/Tamper Alarm Restore pi Exp. ID FR Point # FRNNXXPPPP 3 200 Exp. ID Point #
Supervisory/Tamper point disabled pi Exp. ID FB Point # FBNNXXPPPP 1 571 Exp. ID Point #
Supervisory/Tamper point enabled pi Exp. ID FU Point # FUNNXXPPPP 3 571 Exp. ID Point #
Supervisory/Tamper point trouble pi Exp. ID FT Point # FTNNXXPPPP 1 373 Exp. ID Point #
Supervisory/Tamper point trouble
restore
pi Exp. ID FJ Point # FJNNXXPPPP 3 373 Exp. ID Point #
System-based AUX1 switch alarm pi Exp. ID UA Point # UANNXXPPPP 1 140 Exp. ID Point #
System-based AUX1 switch alarm
restore
pi Exp. ID UH Point # UHNNXXPPPP 3 140 Exp. ID Point #
System-based AUX1 switch disabled pi Exp. ID UB Point # UBNNXXPPPP 1 571 Exp. ID Point #
System-based AUX1 switch enabled pi Exp. ID UU Point # UUNNXXPPPP 3 571 Exp. ID Point #
System-based AUX1 switch trouble pi Exp. ID UT Point # UTNNXXPPPP 1 373 Exp. ID Point #
System-based AUX1 switch trouble
restore
pi Exp. ID UJ Point # UJNNXXPPPP 3 373 Exp. ID Point #
System-based AUX2 switch alarm pi Exp. ID UA Point # UANNXXPPPP 1 140 Exp. ID Point #
System-based AUX2 switch alarm
restore
pi Exp. ID UH Point # UHNNXXPPPP 3 140 Exp. ID Point #
System-based AUX2 switch disabled pi Exp. ID UB Point # UBNNXXPPPP 1 571 Exp. ID Point #
System-based AUX2 switch enabled pi Exp. ID UU Point # UUNNXXPPPP 3 571 Exp. ID Point #
System-based AUX2 switch trouble pi Exp. ID UT Point # UTNNXXPPPP 1 373 Exp. ID Point #
SIA Reporting Format
Contact ID Reporting Format
SIA pi Modifier SIA
Event Description Module ID
# (If Any)
SIA
Event
Codes
Parameter Fixed Length
Format NN - panel
ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
Qualifier Event
Code
Group # Contact #