HH490 User Guide 93
Straight 2 of 5 Industrial Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 82) for additional information. Minimum and
Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Straight 2 of 5 IATA (two-bar start/stop)
<Default All Straight 2 of 5 IATA Settings>
Straight 2 of 5 IATA On/Off
Straight 2 of 5 IATA Redundancy
If you are encountering errors when reading Straight 2 of 5 IATA barcodes, you
may want to adjust the redundancy count. Redundancy adjusts the number of
times a barcode is decoded before transmission, which may reduce the number
of errors. Note that the higher the redundancy count, the longer it will take to
decode the barcode. To adjust the redundancy, scan the Straight 2 of 5 IATA
Redundancy barcode below, then scan a redundancy count between 0 and 10 on
the Programming Chart, beginning on page 211. Then scan the Save barcode.
Default = 0.