164 HH490 User Guide
connected to host). This setting is changed by using the BT_NAM
command, which accepts alphanumeric values. If the name is not
known, a wild- card (*) can be used :*
Note:
Since the base stores all work group settings and transfers to them to scanner
once they are linked, changes are typically done to the base and not to the scanner.
Tag A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS232 configuration settings are
identified with a Tag of 232.
SubTag A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS232 baud rate is BAD.
Data The new value for a menu setting, identified by the Tag and SubTag.
Storage A single character that specifies the storage table to which the
com- mand is applied. An exclamation point (!) performs the
command’s operation on the device’s volatile menu configuration
table. A period (.) performs the command’s operation on the
device’s non-volatile menu configuration table. Use the
non-volatile table only for semi- permanent changes you want
saved through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
^
>
What is the default value for the setting(s).
What is the PAP sub command.
Note:
When using the >, all other commands will return NAK.
?
*
What is the device’s current value for the setting(s).
What is the range of possible values for the setting(s). (The device’s
response uses a dash (-) to indicate a continuous range of values. A
pipe (|) separates items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.

Table of Contents

Other manuals for Honeywell HH490

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HH490 and is the answer not in the manual?

Honeywell HH490 Specifications

General IconGeneral
Duplex scanningNo
Maximum scan size- mm
Optical scanning resolution1280 x 800 DPI
Scanner typeHandheld scanner
Product colorWhite
Quantity per pack1 pc(s)
Sensor type-
Barcode readerYes
Daily duty cycle (max)- pages
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Power supply typeDC
Optional connectivitySerial (RS-232)
Weight and Dimensions IconWeight and Dimensions
Depth72.5 mm
Width125 mm
Height154 mm
Weight130 g