70 HH490 User Guide
0D is the hex value for a CR
The data is output as:
123456
<CR>
Move the cursor to the end
EA Move the cursor to the last character in the input message.
Syntax = EA.
Search Commands
Search forward for a character
F8 Search the input message forward for “xx” character from the current cursor
position, leaving the cursor pointing to the “xx” character.
Syntax = F8xx
where xx
stands for the search character’s hex value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 203
for decimal, hex and character codes.
F8 Example: Send barcode data that starts after a particular character
Search for the letter “D” in barcodes and send all the data that follows, including
the “D.” Using the barcode above:
Command string: F844F10D
F8 is the “Search forward for a character” command
44 is the hex value for “D”
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
DEFGHIJ
<CR>