48 HH490 User Guide
54
49
41
4C
3C
T
I
A
L
left bracket (<)
The whole command line would look like this:
SEQBLK62999943FF6A999954FF7299994DFF;SEQSEP993C3E;SEQSUF99
0D0A;SEQTTS1;SEQISU993E5041525449414C3C
The data is output as:
TSTMSGCODE128MSGPDF417>PARTIAL<
Discard Partial Output Sequence
If you want to discard partial sequences when the output sequence operation is
terminated before completion, scan Discard Partial Sequence.
* Discard Partial Sequence
Output Sequence Timeouts
You can set a timeout for every code in the output sequence defined by the
SEQBLK command. The scanner applies the shortest timeout corresponding to
any of the codes that have been read during the current trigger session. When the
timeout expires, the scanner sends all codes that it has been read in the order
they appear in the sequence defined by SEQBLK.
To specify the timeout, use the SEQTIM command followed by a list of timeouts in
milliseconds. Each timeout is specified as a 4-decimal digit terminated by FF. The
timeout value 9999 is special and indicates that the timeout for that code is
“infinite”.
The number of timeouts specified should correspond to the number of codes in
the sequence defined by SEQBLK. You can specify one additional timeout, which
will apply to codes not matching any member of the sequence. This can be useful
if Require Output Sequence is On/Not Required. If you do not specify an
additional timeout for codes not in the defined sequence, the last timeout
specified by SEQTIM will apply.

Table of Contents

Other manuals for Honeywell HH490

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HH490 and is the answer not in the manual?

Honeywell HH490 Specifications

General IconGeneral
Duplex scanningNo
Maximum scan size- mm
Optical scanning resolution1280 x 800 DPI
Scanner typeHandheld scanner
Product colorWhite
Quantity per pack1 pc(s)
Sensor type-
Barcode readerYes
Daily duty cycle (max)- pages
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Power supply typeDC
Optional connectivitySerial (RS-232)
Weight and Dimensions IconWeight and Dimensions
Depth72.5 mm
Width125 mm
Height154 mm
Weight130 g

Related product manuals