*Jun 26 13:04:33:519 2012 RouterA PBR6/7/PBR Forward Info: -MDC=1; apply next-hop
150
::2.
The output shows that Router A sets the next hop for the received packets to 150::2 according to
IPv6 PBR. The packets are forwarded through Serial 2/0.
# Ping Loopback 0 of Router B from Host A, and set the data length to 200 bytes.
C:\>ping –n 1 -l 200 10::1
Pinging 10::1 with 200 bytes of data:
Reply from 10::1: time=1ms
Ping statistics for 10::1:
Packets: Sent = 1, Received = 1, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 1ms, Maximum = 1ms, Average = 1ms
The debugging information about IPv6 PBR displayed on Router A is as follows:
<RouterA>
*Jun 26 13:20:33:619 2012 RouterA PBR6/7/PBR Forward Info: -MDC=1; Policy:lab1, Node:
20,match succeeded.
*Jun 26 13:20:33:619 2012 RouterA PBR6/7/PBR Forward Info: -MDC=1; apply next-hop
151
::2.
The output shows that Router A sets the next hop for the received packets to 151::2 according to
IPv6 PBR. The packets are forwarded through Serial 2/1.

Table of Contents

Other manuals for HP 5500 EI series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5500 EI series and is the answer not in the manual?

HP 5500 EI series Specifications

General IconGeneral
BrandHP
Model5500 EI series
CategorySwitch
LanguageEnglish

Related product manuals