RADIUS Authentication and Accounting
Commands Authorization
Profile=IN OUT
Enums=Hp-Command-Exception-Types
[Hp-Command-Exception-Types]
0=PermitList
1=DenyList
2. Copy the hp.ini dictionary file to c:\program files\cisco acs 3.2\utils (or
the \utils directory wherever acs is installed).
3. From the command prompt execute the following command:
c:\Program files\CiscoSecure ACS v3.2\utils>
csutil -addudv 0 hp.ini
The zero (0) is the slot number. You will see some processing messages:
Adding or removing vendors requires ACS services to be
re-started. Please make sure regedit is not running as
it can prevent registry backup/restore operations.
Are you sure you want to proceed? (Y or N) y
Parsing [.\hp.ini] for addition at UDV slot [0]
Stopping any running services
Creating backup of current config
Adding Vendor [HP} added as [RADIUS (HP)]
Done
Checking new configuration...
New configuration OK
Re-starting stopped services
4. Start the registry editor (regedit) and browse to
HKEY_LOCAL_MACHINE\software\cisco\CiscoAAA v3.2\NAS Vendors
tree.
Cisco adds the entry into this tree for each custom vendor. The id is 100
+ the slot number used in the previous command (100 + 0, as it was added
in slot 0). Look in the key to verify the vendor name and id.
5. Go to:
HKEY_LOCAL_MACHINE\software\cisco\CiscoAAAv3.2\
CSRadius\ExtensionPoints\002\AssociatedWithVendors
5-31

Table of Contents

Other manuals for HP PROCURVE 2910AL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP PROCURVE 2910AL and is the answer not in the manual?

HP PROCURVE 2910AL Specifications

General IconGeneral
ModelHP ProCurve 2910al
Switching Capacity128 Gbps
Throughput95.2 Mpps
ManagementWeb, CLI, SNMP
Jumbo Frame SupportYes
ManageableYes
Power100-240 VAC
Power SupplyInternal
Operating Temperature0°C to 45°C (32°F to 113°F)
StackingYes
MAC Address Table Size32000 entries
Routing ProtocolRIP, OSPF
FeaturesIPv6, VLAN, QoS, ACLs
Operating Humidity15% to 95% non-condensing
Uplink Ports4
Power over EthernetYes (PoE+ models available)