System LEDs and Switches
Table E-10: Single-Board Mirrored Memory LEDs
Item Description Indicator Status
Off DIMM is not installed.
Green DIMM is installed.
Amber Memory error has occurred on this DIMM.
1 – 4
and
10 – 13
DIMMs 1 – 8
Flashing amber Configuration error has occurred.
Off Memory board is offline.
Green Memory board is online.
Flashing green Memory board is busy.
6 Memory
Status
Amber Memory error has occurred on this memory board.
7 Ready to Hot
Plug
Off Do not remove memory board—single-board mirrored
memory does not support hot-plug capability.
Off Memory board is not configured for mirrored memory.
Green Single-board mirrored memory is functioning properly.
9 Mirroring
Status
Amber Memory error has occurred and system has failed over
to the mirrored bank.
Off Memory board is not seated properly or locking switch
is not engaged; memory board can be removed safely.
All LEDs
Flashing amber
CAUTION: Memory board is in use; relock it
immediately.
HP ProLiant DL580 Generation 2 Server Setup and Installation Guide E-11
HP CONFIDENTIAL
Writer: Karen Hale File Name: p-appe System LEDs and Switches3.doc
Codename: Wave Part Number: 230835-003 Last Saved On: 6/26/03 9:49 AM