P9000 for Business Continuity Manager
Software User Guide
Abstract
This manual describes how to use the following program products: HP StorageWorks P9000 for Business Continuity Manager
Software, HP StorageWorks P9000 for Business Continuity Manager Extended CT Group Software, and HP StorageWorks
P9000 for Business Continuity Manager Continuous Access Journal 4x4 Extended CT Software.
HP Part Number: T5253-96059
Published: October 2011
Edition: Eleventh

Table of Contents

Other manuals for HP XP P9500

Questions and Answers

  • M
    morenokimberlyAug 28, 2025
    What to do if the status of pairs and/or logical paths is not displayed correctly in HP XP P9500?
    • N
      Nicholas YoungAug 29, 2025
      Make sure that the correct CU image is selected. Check whether you selected correct items or options in Cnt Ac-J windows, such as the DKC Operation window, the Pair Operation window, and the Display Filter dialog box.
  • A
    Amanda DennisAug 28, 2025
    What happens to HP XP P9500 Software Cnt Ac-J Z pairs during a planned power outage?
    • K
      Kristen BishopAug 28, 2025
      During a planned power outage to the primary system, the Cnt Ac-J Z pairs are temporarily suspended. No recovery procedure is required. The primary system automatically removes the suspension condition when the system is powered on.
  • R
    robert16Aug 27, 2025
    What to do if HP XP P9500 shows 'Communication error'?
    • S
      Stephanie BaileyAug 27, 2025
      A timeout error has occurred in the path between the primary and secondary systems. Delete the failed path and retry.
  • B
    Bryce PowellSep 5, 2025
    How to resume HP XP P9500 pair suspended by R-VOL?
    • W
      William SchmidtSep 5, 2025
      If the user suspended the HP Software pair from the MCU or RCU using the R-VOL for Suspend Kind option, resynchronize the pair from the MCU (Resume Pair).
  • I
    Ian JonesSep 8, 2025
    What to do if the HP XP P9500 Remote Web Console hangs?
    • S
      Stephanie Nguyen DDSSep 8, 2025
      If the HP Software Remote Web Console hangs, ensure the issue isn't with your computer, Ethernet hardware, or software. Restart your computer, which won't impact ongoing Cnt Ac-J operations. Verify all Cnt Ac-J requirements are met. Confirm that the primary and secondary systems, along with remote copy connections, are powered on and fully operational, including NVS and cache. Double-check all entered values and parameters in the Remote Web Console for accuracy, such as the secondary system S/N and path parameters. Avoid using Performance Monitor during these operations.
  • B
    Benjamin GrahamSep 12, 2025
    How to resolve HP XP P9500 Software Pair-Port Type Mismatch error?
    • B
      bobbyrichardsonSep 12, 2025
      If you get a 'Pair-Port Type Mismatch' error in HP Software, it means the specified port in the secondary system isn't configured as an RCU Target port. Make sure that the specified port in the secondary system is configured as an RCU target port.
  • J
    John MooreSep 14, 2025
    What causes the error: primary storage system could not find valid control information in HP XP P9500?
    • G
      georgewilliamsSep 15, 2025
      If the primary storage system could not find valid control information in its nonvolatile memory during the IMPL procedure in HP Software, and this error occurs only if the primary storage system is without power for more than 48 hours (power failure and fully discharged batteries), restore the pair (pairresync) from the primary storage system. The primary storage system performs an initial copy operation in response to the pairresync request, so that the entire P-VOL is copied to the S-VOL.
  • M
    mgrossSep 23, 2025
    What to do if I see a fence message displayed on the console of my HP Disk array system?
    • C
      Christine GeorgeSep 23, 2025
      If a fence message appears on the console, first check for a failed storage path. If a failed path is found, toggle the RESTART switch and retry the operation. Should the fence message reappear, it is recommended to contact the support center for assistance.
  • M
    Michelle BrownAug 25, 2025
    What does 'Pair-Port Number Mismatch' mean in HP XP P9500 Software?
    • D
      deanaaronAug 26, 2025
      The 'Pair-Port Number Mismatch' error in HP Software indicates that the specified port in the secondary system is physically disconnected from the primary system. Make sure of the following: * That you specified the correct secondary system port. Correct the port number if necessary. * The primary and the secondary systems ports are connected with cables. If the systems are not connected by cables, connect them and retry the operation. * That the topology settings of ports on the primary and secondary systems are correct.
  • J
    John GillespieAug 25, 2025
    What to do if HP Software shows 'Serial Number Mismatch'?
    • D
      Donna CannonAug 26, 2025
      If the HP Software shows a 'Serial Number Mismatch', it means the serial number (S/N) of the secondary system does not match the specified serial number. Ensure that you entered the correct secondary system S/N and path parameters (for example, primary and secondary system port, and controller ID). After that, delete the failed path. You may need to change the minimum paths setting or delete the secondary system in order to delete the path. After deletion finishes, add the path and the secondary system back. Make sure that you entered the correct controller ID, and also make sure that the topology settings of the primary and secondary system ports are correct.

Summary

Overview of HP P9000 for Business Continuity Manager Software

Business Continuity Manager with replication products

The 4 x4 x4 Cascade configuration

Explains the 4x4x4 Cascade configuration, combining 4x4 and 3DC Cascade configurations.

Understanding Business Continuity Manager functions

Functions That Support Disaster Recovery

Describes Business Continuity Manager functions that support disaster recovery, including Reverse Resync and Consistency Preservation.

Preparing to use Business Continuity Manager

Configuration Definitions

Defining a 2 DC configuration

Explains how to define a 2DC configuration with one storage system installed at each site.

Defining a 3 DC Cascade configuration

Details the procedure for defining a 3DC Cascade configuration.

Defining a 3 DC Multi-Target configuration

Describes how to define a 3DC Multi-Target configuration.

Defining a 4 x4 configuration

Details how to define a 4x4 configuration.

Importing copy groups

Generating a copy group definition file by using CSV files

Explains generating copy group definition files using comma-separated value (CSV) files.

Maintenance and Troubleshooting Operations

Failover Procedure

Provides the step-by-step procedure for performing a failover.

Failback Procedure

Details the step-by-step procedure for performing a failback.

Actions to be Taken When the Delta Resync Function Cannot be Set Up or Operated Successfully

Provides troubleshooting steps for errors encountered with the delta resync function.

Performing Primary Site Storage System Maintenance

Explains procedures for primary site storage system maintenance.

Performing Local Site Storage System Maintenance

Details procedures for local site storage system maintenance.

Automatic operation using BCM Monitor

Troubleshooting procedures provided by BCM Monitor

Details troubleshooting procedures for BCM Monitor issues.

Troubleshooting

Troubleshooting Failures

Explains common system failures that might occur with Business Continuity Manager.

Error Notification

Describes the function that reports errors when volume status changes to an error state.

Recovering from a Failure

Provides procedures for recovering from various types of failures.

Performing Operations When a Failure Occurs for a Volume in a Copy Group

Outlines methods for performing operations when a copy group volume has a hardware failure.